LIFTINGSAFETY
"TAL 1000lb Series" Linear Actuator

"TAL 1000lb Series" Linear Actuator

Heavy duty linear actuator.

Model: 

TAL 1000lb Series / SLA-4062

"TAL 1000lb Series" Linear Actuator

TAL 1000lb Series Linear Actuator TAL 1000lb Series Dimensional Diagram TAL 1000lb Series Wire Diagram

TAL 1000lb Series Linear Actuator

Features & Benefits

  • Heavy duty design for long life in tough applications.
  • Adjustable limit switches on the motor end save space.
  • Aluminium housing and outer tube.
  • Stainless steel translating tube.
  • Double Clevis mounting.
  • Automatic reset thermal overload motor protection.

Options

  • Potentiometer Feedback.
  • Capacitor.
  • Bellows Boot.

TAL 1000lb Series Dimensional Diagram

TAL 1000lb Series Dimensional Diagram

TAL 1000lb Series Wire Diagram

TAL 1000lb Series Wire Diagram

TAL 1000lb Series Linear Actuator Specifications

Part Number Rated Load Stroke Length Retracted Length Voltage Current Draw at Rated Load (A) Speed at Rated Load Limit Switch Capacitor Duty Cycle at Rated Load Weight
lbs N in mm in mm in/s mm/s lbs N
TAL10-1A20-4 1,000 4,448 4 101.6 12 304.8 115 Vac
(60 Hz)
4 0.4 11 Yes SK6405-7-15
(50 MFD)
17.5% 19 84.5
TAL10-1A20-8 8 203.2 16 406.4 21 93.4
TAL10-1A20-12 12 304.8 20 508.0 21 93.4
TAL10-2A20-4 1,000 4,448 4 101.6 12 304.8 220 / 230 Vac
(50 / 60 Hz)
2.0/2.5 0.45/ 0.37 11.4/ 9.4 Yes SK6405-7-14
(15 MFD)
17% (14%) 19 84.5
TAL10-2A20-8 8 203.2 16 406.4 21 93.4
TAL10-2A20-12 12 304.8 20 508.0 21 93.4
Part N° Rated Load (lbs) Rated Load (N) Stroke Length (in) Stroke Length (mm) Retracted Length (inch) Retracted Length (mm) Voltage Current Draw at Rated Load (A) Speed at Rated Load (in/s) Speed at Rated Load (mm/s) Limit Switch Capacitor Weight (lbs) Weight (N) Unit Price Quantity
4062-T21926
TAL10-1A20-4
1,000 4,448 4 101.6 12 304.8 115 Vac (60 Hz) 4 0.4 11 Yes SK6405-7-15 (50 MFD) 19 84.5 Quote Required
4062-T21927
TAL10-1A20-8
1,000 4,448 8 203.2 16 406.4 115 Vac (60 Hz) 4 0.4 11 Yes SK6405-7-15 (50 MFD) 21 93.4 Quote Required
4062-T21928
TAL10-1A20-12
1,000 4,448 12 304.8 20 508.0 115 Vac (60 Hz) 4 0.4 11 Yes SK6405-7-15 (50 MFD) 21 93.4 Quote Required
4062-T21929
TAL10-2A20-4
1,000 4,448 4 101.6 12 304.8 220 / 230 Vac (50 / 60 Hz) 2.0/2.5 0.45/ 0.37 11.4/ 9.4 Yes SK6405-7-14 (15 MFD) 19 84.5 Quote Required
4062-T21930
TAL10-2A20-8
1,000 4,448 8 203.2 16 406.4 220 / 230 Vac (50 / 60 Hz) 2.0/2.5 0.45/ 0.37 11.4/ 9.4 Yes SK6405-7-14 (15 MFD) 21 93.4 Quote Required
4062-T21931
TAL10-2A20-12
1,000 4,448 12 304.8 20 508.0 220 / 230 Vac (50 / 60 Hz) 2.0/2.5 0.45/ 0.37 11.4/ 9.4 Yes SK6405-7-14 (15 MFD) 21 93.4 Quote Required
   

TAL 1000lb Series Linear Actuator

Features & Benefits

  • Heavy duty design for long life in tough applications.
  • Adjustable limit switches on the motor end save space.
  • Aluminium housing and outer tube.
  • Stainless steel translating tube.
  • Double Clevis mounting.
  • Automatic reset thermal overload motor protection.

Options

  • Potentiometer Feedback.
  • Capacitor.
  • Bellows Boot.

TAL 1000lb Series Dimensional Diagram

TAL 1000lb Series Dimensional Diagram

TAL 1000lb Series Wire Diagram

TAL 1000lb Series Wire Diagram

TAL 1000lb Series Linear Actuator Specifications

Part Number Rated Load Stroke Length Retracted Length Voltage Current Draw at Rated Load (A) Speed at Rated Load Limit Switch Capacitor Duty Cycle at Rated Load Weight
lbs N in mm in mm in/s mm/s lbs N
TAL10-1A20-4 1,000 4,448 4 101.6 12 304.8 115 Vac
(60 Hz)
4 0.4 11 Yes SK6405-7-15
(50 MFD)
17.5% 19 84.5
TAL10-1A20-8 8 203.2 16 406.4 21 93.4
TAL10-1A20-12 12 304.8 20 508.0 21 93.4
TAL10-2A20-4 1,000 4,448 4 101.6 12 304.8 220 / 230 Vac
(50 / 60 Hz)
2.0/2.5 0.45/ 0.37 11.4/ 9.4 Yes SK6405-7-14
(15 MFD)
17% (14%) 19 84.5
TAL10-2A20-8 8 203.2 16 406.4 21 93.4
TAL10-2A20-12 12 304.8 20 508.0 21 93.4

Contact Us About This Product

LiftingSafety uses cookies to improve your user experience,
To accept this, please click the 'accept' button below.

Find out more